1-866-4 JJSTECH(1-866-455-7832)

E Instruments AQ VOC Handheld TVOCs Monitor

Item #:
XXYY-AQ-VOC
Brand:
E Instruments
E Instruments AQ VOC Handheld TVOCs Monitor
$3,939.00
Qty
Send This Page to a Friend

Ask an Expert

Our tech experts are ready to help!

1-866-4 JJSTECH (1-866-455-7832)

Email Us
Share this product:
E Instruments AQ VOC Handheld TVOCs Monitor

E Instruments AQ VOC Handheld TVOCs Monitor

$3,939.00
Choose Options

AQ VOC Handheld TVOCs Monitor by E Instruments

The SI-AQ VOC Monitor is the ideal instrument for you should your specific application require testing for Volatile Organic Compounds (VOCs) or potentially harmful gasses such as Carbon Monoxide (CO). In addition, the (Si-VOC) Si-AQ VOC Monitor can an also be outfitted with up to three (3) Gases sensors in total among VOC, CO2, CO, Formaldehyde, NO2, NO, O2, SO2 & H2S in addition to measuring Relative Humidity, Ambient Temperature and Barometric Pressure.

Accurate / Reliable / Robust / Fast

  • Dynamic PID TVOC Sensor: 0 - 20,000 ppb or 0 - 200 ppm
  • Temp., %RH, & Barometric Pressure Included
  • Real-Time Data Logging
  • Active Internal Sampling Pump
  • Large Internal Memory (2,000 Tests)
  • Protective Magnetic Rubber Boot
  • Optional Wireless Printer
  • Optional Handheld Probe

  • Select Up To 3 Gases in Total: TVOCs, CO2, CO, Formaldehyde, NO2, NO, O2, SO2, H2S
  • Long Lasting Rechargeable Battery & AC Charger
  • Light Weight & Durable
  • Si-AQ PC Software & USB Cable

AQ VOC Kit includes:

  • Temperature, %RH, Wet Bulb, Dew Point
  • Barometric Pressure
  • PC Software & USB Cable
  • Real-Time Continuous Data Logging
  • Bluetooth® Connectivity
  • Protective Carrying Case
  • Continuous Active Internal Sampling Pump
  • Long Lasting Battery & AC Charger
  • Factory Calibration Certificate
  • Quick Start Guide
Specifications:
Parameter Sensor Range Resolution Accuracy
Low Range VOC PID 5 - 95 % 0.1 % ±2 % RH
High Range VOC PID -40 to 257 °F
-40 to 125 °C
0.1 °F
0.1 °C
±0.4 °F (32 - 140 °F)
±0.4 °C (0 - 60 °C)
Relative Humidity Capacitive 260 - 1,260 mbar 1 mbar ±2 mbar
Ambient Temperature Pt100 -40 inH2O to 40 inH2O
-100 mbar to 100 mbar
0.1 inH2O
0.1 mbar
±1 % rdg
Barometric Pressure Piezoresistive 0 - 2,000 °F
0 - 1,100 °C
1 °F
1 °C
5 °F / 3 °C or 2 % rdg
Differential Pressure Piezoresistive 0 - 300 ft/sec
0 - 91 m/s
1 ft/sec
1 m/s
-
Temperature Type K T1 Tc K 0 - 2,000 °F
0 - 1,100 °C
1 °F
1 °C
5 °F / 3 °C or 2 % rdg
Air Velocity Calculated 0 - 300 ft/sec
0 - 91 m/s
1 ft/sec
1 m/s
-
Electromagnetic Compatibility EN 61326-1, Portable Equipment

Si-AQ VOC Ordering Code
Parameter Sensor Range Resolution Accuracy
Si-AQ VOC Cell (20,000 ppb) Low Range VOC PID 0 - 20,000 ppb
0 - 46,000 µg/m
   
Si-AQ VOC Cell (200 ppm) High Range VOC PID 0 - 200 ppm
0 - 460 mg/m
   
Si-AQ CO2 Sensor (5000 ppm) Carbon Dioxide (CO2) NDIR 0 - 5,000 ppm 1 ppm ±2 % rdg ±10 ppm
Si-AQ CO Cell (0 - 200 ppm) Carbon Monoxide (CO) EC 0 - 200 ppm 0.1 ppm ±4 % rdg ±0.5 ppm
Si-AQ CH2 O Cell (0 - 10 ppm) Formaldehyde (CH2O) EC 0 - 10,000 ppb 1 ppb ±5 % rdg ±50 ppb
Si-AQ H2 S Cell (0 - 100 ppm) Hydrogen Sulfide (H2S) EC 0 - 100 ppm 1 ppm ±4 % rdg ±0.5 ppm
Si-AQ NO2 Cell (0 - 20 ppm) Nitrogen Dioxide (NO2) EC 0 - 20 ppm 0.1 ppm ±4 % rdg ±0.5 ppm
Si-AQ O2 Cell (0 - 25 %) Oxygen (O2) EC 0 - 25 % 0.1 % ±0.1 % vol rdg
Si-AQ SO2 Cell (0 - 20 ppm) Sulfur Dioxide (SO2) EC 0 - 20 ppm 0.1 ppm ±4 % rdg ±0.5 ppm
Si-AQ NO Cell (0 - 250 ppm) Nitric Oxide (NO) EC 0 - 250 ppm 0.1 ppm ±4 % rdg ±0.5 ppm

Questions & Answers


There are no questions or answers for this item.