1-866-4 JJSTECH(1-866-455-7832)

E Instruments AQ PRO Indoor Air Quality Monitor

Item #:
XXYY-AQ-PRO
Brand:
E Instruments
E Instruments AQ PRO Indoor Air Quality Monitor
$1,468.00
Qty
Send This Page to a Friend

Ask an Expert

Our tech experts are ready to help!

1-866-4 JJSTECH (1-866-455-7832)

Email Us
Share this product:
E Instruments AQ PRO Indoor Air Quality Monitor

E Instruments AQ PRO Indoor Air Quality Monitor

$1,468.00
Choose Options

AQ PRO Indoor Air Quality Monitor by E Instruments

Our handheld Si-AQ Pro also be customized to support whatever specific type of toxic gas sensor(s) a warehouse air quality testing professional may need.

Accurate / Reliable / Robust / Fast

  • Up to 3 Gases
  • Temp., %RH, & Barometric Pressure Included
  • Real-Time Data Logging
  • Active Internal Sampling Pump
  • Large Internal Memory (2,000 Tests)
  • Protective Magnetic Rubber Boot
  • Optional Wireless Printer
  • Optional Handheld Probe

  • Select Up To 3 Gases: CO2, CO, NO2, NO, O2, SO2, H2S, Formaldehyde
  • Long Lasting Rechargeable Battery & AC Charger
  • Light Weight & Durable
  • Si-AQ PC Software & USB Cable

AQ Pro Kit includes:

  • Temperature, %RH, Wet Bult, Dew Point
  • Barometric Pressure
  • PC Software & USB Cable
  • Real-Time Continuous Data Logging
  • Bluetooth® Connectivity
  • Continuous Active Internal Sampling Pump
  • Differential Pressure
  • Long Lasting Battery & AC Charger
  • Factory Calibration Certificate
  • Quick Start Guide
Specifications:
Parameter Sensor Range Resolution Accuracy
Relative Humidity Capacitive 5 - 95 % 0.1 % ±2 % RH
Ambient Temperature Pt100 -40 to 257 °F
-40 to 125 °C
0.1 °F
0.1 °C
±0.4 °F (32 - 140 °F)
±0.4 °C (0 - 60 °C)
Barometric Pressure Piezoresistive 260 - 1,260 mbar 1 mbar ±2 mbar
Differential Pressure Piezoresistive -40 inH2O to 40 inH2O
-100 mbar to 100 mbar
0.1 inH2O
0.1 mbar
±1 % rdg
Temperature Type K T1 Tc K 0 - 2,000 °F
0 - 1,100 °C
1 °F
1 °C
5 °F / 3 °C or 2 % rdg
Air Velocity Calculated 0 - 300 ft/sec 0 - 91 m/s 1 ft/sec
1 m/s
-
Electromagnetic Compatibility EN 61326-1, Portable Equipment

Si-AQ Pro Ordering Code
Parameter Sensor Range Resolution Accuracy
Si-AQ CO2 Sensor (0 - 5000 ppm) Carbon Dioxide (CO2) NDIR 0 - 5,000 ppm 1 ppm ±2 % rdg ±10 ppm
Si-AQ CO Cell (0 - 200 ppm) Carbon Monoxide (CO) EC 0 - 200 ppm 0.1 ppm ±4 % rdg ±0.5 ppm
Si-AQ CH2 O Cell (0 - 10 ppm) Formaldehyde EC 0 - 10 ppm
0 - 10,000 ppb
1 ppb ±5 % rdg ±50 ppb
Si-AQ H2S Cell (0 - 100 ppm) Hydrogen Sulfide (H2S) EC 0 - 100 ppm 1 ppm ±4 % rdg ±0.5 ppm
Si-AQ NO2 Cell (0 - 20 ppm) Nitrogen Dioxide (NO2) EC 0 - 20 ppm 0.1 ppm ±4 % rdg ±0.5 ppm
Si-AQ O2 Cell (0 - 25%) Oxygen (O2) EC 0 - 25 % 0.1 % ±0.1 % vol rdg
Si-AQ SO2 Cell (0 - 20 ppm) Sulfur Dioxide (SO2) EC 0 - 20 ppm 0.1 ppm ±4 % rdg ±0.5 ppm
Si-AQ NO Cell (0 - 250 ppm) Nitric Oxide (NO) EC 0 - 250 ppm 0.1 ppm ±4 % rdg ±0.5 ppm

Questions & Answers