- All Products
- Shop by Brands
- BW Technologies
- BW Technologies
- BW Technologies Monitors
- Models
- BW Clip
- BW Clip4
- GasAlertClip Extreme
- GasAlert Extreme
- GasAlertMicroClip XT
- GasAlertMicroClip XL
- GasAlertMicroClip X3
- GasAlertQuattro
- GasAlertMax XT II
- GasAlertMicro 5 Series
- SamplerPak
- IntelliDox Docking System
- MicroDock II
- BW Ultra
- BW Solo
- Gas Monitors
- Gas Monitor Manufacturers
- BW Technologies
- Bacharach
- Biosystems
- Crowcon
- Gas Clip Technologies
- GfG Instruments
- GMI/Detcon
- Honeywell Analytics
- Industrial Scientific
- MSA
- RAE Instruments
- RKI Instruments
- Calibration Gas
- Combustion Analyzers
- Water Quality
- Reliability Instruments
- Refractometers
- HVAC
- Weather
- Temperature
- Laboratory
- Sound
- IAQ
- Electrical
- All Categories
E Instruments E8500-OCN-0-12 Portable Industrial Flue Gas & Emissions Analyzer with O2 (0-25%), CO (0-8000ppm), & NO/NOx (0-4000ppm) Gas Sensors
Item #:
E8500-OCN-0-12
Brand:
E Instruments
Share this product:
E Instruments E8500 Portable Industrial Flue Gas and Emissions Analyzer
The E8500 Portable Industrial Flue Gas and Emissions Analyzer is the latest in gas detection equipment with Bluetooth technology. Utilizing up to 9 different gas sensors, the technologically advanced detector is designed to fit almost any industrial application. The unit is designed to monitor an array of combustible gases while recording real time data and storing the information for future analysis. The state of the art software package that is included is easy to install and use. Thanks to the thoughtful design and advanced internal technology, the E8500 is one of the most reliable and useful gas analyzers on the market.
State of the Art Technology
The E8500 comes standard with an EGAS software package. The package saves and graphs data in real time. Data can be analyzed both in the field and in a laboratory. The gas analyzer uses Bluetooth technology to communicate data between the unit and a computer. The Bluetooth module is also included with the EGAS software package. Users can also export this data to various programs for more specialized reports.
Another useful application of advanced technology is evident in the LCD display screen. The screen has a continuous backlight and is automatically rotated. The parameters in the display can be zoomed in or out based on user controls.
Exclusive Features
The E8500 Portable Gas and Emissions Analyzer is packed with exclusive features
- Built In Thermoelectric Chiller
- Automatic Condensate Drain Pump
- Wireless Remote Printer
- CO Dilution Auto Range
- True NOx Measurements
- Up to 9 Total Gas Sensors (O2, CO2, CO, NO, NO2, NOx, SO2, H2S, CxHy, Flue Gas and Air Temperature, Draft and Differential Pressure, and Stack Gas Velocity)
- NDIR Sensors
- Gas Velocity with Pitot Tube
- Rechargeable Battery
- Internal Memory
- Wireless Communications Capabilities
- PC Software with Bluetooth technology
Thermoelectric Chiller with Auto Condensate Drain
To help protect the integrity and life of the analyzer, developers implemented several safety devices. One of which is the thermoelectric chiller with an auto condensate drain. The internal thermoelectric chiller recognizes and removes water and water vapor from the flue gas sample. This prevents combustion gases from bubbling from the gas phase into the condensate. The built-in condensate drain pump automatically pumps the accumulated water out through the bottom of the unit. These automatic features are convenient and necessary for preserving the integrity of the machine.
The E8500 can utilize up to 9 sensors. This entails up to 6 electrochemical sensors and up to 3 NDIR sensors. Each sensor has its own range, resolution, and accuracy rating. Flue gas and air temperature measurements are standard features while the differential temperature is used as part of the efficiency calculation. The unit has two pressure inputs for measuring differential pressure. The E8500 comes standard with a complete factory calibration. With span gas cylinders, the unit can be easily recalibrated. E Instruments International recommends recalibration at least once every year to ensure equipment accuracy.
Parameter |
Sensor |
Range |
Resolution |
Accuracy |
O2 | Electrochemical | 0 - 25% | 0.1% | ±0.1% vol |
CO | Electrochemical | 0 - 8000 ppm | 1 ppm | <300 ppm=±10 ppm up to 2000 ppm=±4% >2000 ppm=±10% |
CO Auto Range | Electrochemical | 0 - 20,000 ppm | 1 ppm | ±10% rdg |
CO | NDIR | 0 - 15.00% | 0.01% | ±3% rdg. |
NO | Electrochemical | 0 - 4000 ppm | 1 ppm | <125 ppm=±5 ppm up to 4000 ppm=±4% |
NO2 | Electrochemical | 0 - 1000 ppm | 1 ppm | <125 ppm=±5 ppm 2 up to 1000 ppm=±4% |
Low NO and/or Low NO2 | Electrochemical | 0 - 500 ppm | 0.1 ppm | <50 ppm=±2 ppm up to 500 ppm=±4% |
NOx | Calculated | 0 - 5000 ppm | 1 ppm | |
SO2 | Electrochemical | 0 - 4000 ppm | 1 ppm | <125 ppm=±5 ppm up to 4000 ppm=±4% |
CO2 | Calculated | 0 - 99.9% | 0.1% | |
CO2 | NDIR | 0 - 20.0% | 0.1% | ±3% rdg. |
CxHy | NDIR | 0 - 3.00% | 0.01% | ±3% rdg. + 0.01% |
H2S | Electrochemical | 0 - 500 ppm | 1 ppm | <125 ppm=±5 ppm 2 up to 500 ppm=±4% |
Tair | Pt100 | -10 - 99.9°C 14.0 - 212.0°F |
0.1°C 0.1°F |
± 2°C ± 3°F |
Tgas | Tc K | 0 - 999.9°C 32.0 - 1830°F |
0.1°C 0.1°F |
± 3°C ± 5°F |
ΔT | Calculated | 0 - 999.9°C 32.0 - 1830°F |
0.1°C 0.1°F |
|
Pressure/Draft | Bridge | ±40.0 inH2O | 0.1 inH2O | ±1% rdg. |
Excess Air | Calculated | 1.00 - infinity | 0.01 | |
Gas Velocity | Calculated | 0 - 99.9 m/s 0 - 330 ft/s |
0.1 m/s 0.1 ft/s |
|
Efficiency | Calculated | 1 - 99.9% | 0.1% |