- All Products
- Shop by Brands
- BW Technologies
- BW Technologies
- BW Technologies Monitors
- Models
- BW Clip
- BW Clip4
- GasAlertClip Extreme
- GasAlert Extreme
- GasAlertMicroClip XT
- GasAlertMicroClip XL
- GasAlertMicroClip X3
- GasAlertQuattro
- GasAlertMax XT II
- GasAlertMicro 5 Series
- SamplerPak
- IntelliDox Docking System
- MicroDock II
- BW Ultra
- BW Solo
- Gas Monitors
- Gas Monitor Manufacturers
- BW Technologies
- Bacharach
- Biosystems
- Crowcon
- Gas Clip Technologies
- GfG Instruments
- GMI/Detcon
- Honeywell Analytics
- Industrial Scientific
- MSA
- RAE Instruments
- RKI Instruments
- Calibration Gas
- Combustion Analyzers
- Water Quality
- Reliability Instruments
- Refractometers
- HVAC
- Weather
- Temperature
- Laboratory
- Sound
- IAQ
- Electrical
- All Categories
GfG CS 21 Fixed Gas Transmitter, HCFC-22 (CHClF2) (6 Cable), 50 to 5000 ppm - 2216017
Item #:
2216017
Brand:
GfG
Share this product:
2216017 CS 21 Fixed Gas Transmitter, HCFC-22 (CHClF2) (6 Cable), 50 to 5000 ppm by GfG
The CS 21 transmitter uses the proven chemosorption detection principle for detection of toxic gases, vapors and combustibles. The rapid response of the transmitter provides opportunity to take counter measures and thereby limit damages. The long life of the sensors makes the CS 21 a low-cost solution for your detection needs. A transmitter can be continuously operated for more than 5 years.
Wall mount installation is straightforward. The distance between transmitter and controller can be greater than 500 m. A rugged aluminum casing protects the sensor and electronics from splashes of water and dirt. The transmitter must not be operated in EX-areas. For measurement of combustible gases in the LEL range the gas needs to be sampled by pump. In this case the EX-protection needs to be guaranteed with suitable external components (e.g.flame-protection).
- High sensitivity to a broad range of refrigerants
- Long sensor life
- Fast response
Gases | Detection range |
CH2Cl2 | 20-300 ppm |
CH3Cl | 20-300 ppm |
CH4 | 5-50% or 100% LEL |
CH4O | 20-1,000 ppm |
CH4S | 10-100 ppm |
CHCl2F | 30-3,000 ppm |
CHCl2F2 | 20-1,000 or 5,000 ppm |
C2Cl3F3 | 30-3,000 ppm |
C2Cl4 | 20-300 ppm |
C2H2F4 | 20-500, 1,000 or 5,000 ppm |
C2H6O | 30-2,000 ppm |
C2HCl3 | 20-300 ppm |
C3H3N | 30-5,000 ppm |
C3H6O | 5-100% LEL |
C3H6O | 20-300 ppm |
C3H8 | 5-50 or 100% LEL |
C4H4O | 20-1,000 ppm |
C4H10 | 5-50% or 100% LEL |
C6H6 | 20-300 ppm |
C6H14 | 20-500 ppm |
C7H8 | 30-500 or 1,000 ppm |
C8H8 | 20-500 or 1,000 ppm |
C8H10 | 20-500 or 5,000 ppm |
C8H10 | 5-50% LEL |
C9H20 | 20-1,000 ppm |
C9H20 | 5-50% LEL |
CCl3F | 20-2,000 ppm |
CO | 20-300 or 1,000 ppm |
H2 | 20-10,000 ppm |
NH3 | 20-300, 1,000, 3,000 or 10,000 ppm |
Detection principle | Chemosorption |
Response time | tA < 14 seconds |
Output signal | 0.2-1 mA 4-20 mA |
Gas supply | Diffusion through stainless steel sinter metal filter |
Power supply | 10 to 32 V, 300 mA (provided by controller) |
Humidity | 20 to 96 % r.h., non condensing |
Expected sensor life | Greater than 5 years |
Pressure | 920 to 1,100 hPa |
Casing protection | IP 54, dust and splashed water protection |
Ambient temperature | -22 to +131°F / -30 to +55°C |
Cable connection | Shielded cable 3 x 0.75 mm up to 500 m, 3 x 1.5 mm for more than 500 m PG11 cable gland |
Weight | 13.05 ounces (370 grams) |
Dimensions | 3.94x3.94x2 inches (100x100x57 mm) (HxWxD) |