1-866-4 JJSTECH(1-866-455-7832)

GfG 25 Series Controller Panel with one Input Channel, 4-20 mA Output, Horn and Strobe - 2210-001

Item #:
2210-001
Brand:
GfG
GfG 25 Series Controller Panel with one Input Channel, 4-20 mA Output, Horn and Strobe - 2210-001
$945.00
Qty
Send This Page to a Friend

Ask an Expert

Our tech experts are ready to help!

1-866-4 JJSTECH (1-866-455-7832)

Email Us
Share this product:
GfG 25 Series Controller Panel with one Input Channel, 4-20 mA Output, Horn and Strobe - 2210-001

GfG 25 Series Controller Panel with one Input Channel, 4-20 mA Output, Horn and Strobe - 2210-001

$945.00

2210-001 25 Series Controller Panel with one Input Channel, 4-20 mA Output, Horn and Strobe by GfG

Simple and Effective

The 25 series control panel is available in a single channel (2210-001 and 2210-00110) or a one to four channel (2210-004 and 2210-00410) version. The panel comes complete with controller, local display horn and strobe. The single channel version also features a 4-20 mA output

Alarm Points

Each alarm can be adjusted separately. The alarm values can be freely adjusted within the detection range. Every alarm point value can be factory programmed to be latching/non-latching and resettable/non-resettable.

Alarm Relays

The controller provides four voltage-free relays for the three alarms and one fault warning. The relays may be used to control additional alarm devices like lights or horns.

Transmitters/Sensors

The 25 series control panel may be connected to any available GfG transmitter for detection of oxygen (O2), combustible gases (LEL) or any transmitter from a wide range of toxic gases.

Features

  • Complete controller package available in single channel or 1-4 channel configurations
  • Compact design
  • Intuitive push button operation
  • 4-20 mA input standard (factory configurable to 0.2-1 mA)
  • 3 user-adjustable alarm hysteresis
  • Rugged metal housing
  • Easy installation
  • 4 relays (3 alarm and 1 fault)
  • Factory configured alarm functions include: Latching/non-latching, Resettable/non-resettable, Time delay, Rapid rise alarm for combustible setups
  • Local display, horn and strobe
  • 4-20 mA output (2210-001 and 2210-00110 only)
Control Panels Any available GfG gas transmitter.
2200-001: 1 transmitter
2210-004: 1 to 4 transmitters (same EC type)
*2210-00110: 1 channel w/2 amp power supply
*2210-00410: 1 to 4 channel w/2 amp power supply
2000230 - push button reset (optional)
Humidity 0 to 99% r.h. non-condensing
Temperature range 32º to +131ºF (0 to +55ºC)
Pressure 700 to 1,300 hPA
Power supply 24 VDC, 1 Amp wall pack
CULUSA
*2 amp integration
Weight 6.5 lbs (2.95 kg)
Dimensions 11x7x2.75 inches (17.9x17.8x7 cm) (HxWxD)
Display 3-digit LED display
1 LED green - operational status
1 LED yellow - fault
3 LED red - alarm
Display of maximum / minimum values
Alarms 3 alarm points
User adjustable within the detection range
Alarm Functions Available Exceeding / descending
Latching / non-latching
Resettable / non-resettable
Hysteresis adjustable
Delay-time 0 to 2 minutes
Relays 3 alarm points, 1 fault - voltage free
Factory setting
A1 - strobe
A2 - open
A3 - horn
Fault - open
Voltage: 250 VAC 50/60 Hz or 250 VDC maximum
Output signal Linear 4-20 mA (2210-001 and 2210-00110 only)
Horn Low - 70 db at 10 ft
High - 83 db at 10 ft
Strobe Bright red, flashing

Datasheets & User Manuals

Questions & Answers


There are no questions or answers for this item.